Generac 0047210 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Générateurs Generac 0047210. Generac 0047210 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Owner’s Manual
ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT
INSTALLATION!!
DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!
This manual should remain with the unit.
Not intended for use in critical life support applications.
!
!
Liquid-cooled, Prepackaged
Standby Generators
Model Numbers
0047210, 0047220,
0047230, 0047240,
0047250, 0047251,
0047252, 0047253,
0047260
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - Owner’s Manual

Owner’s ManualONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPTINSTALLATION!!DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!This manual shoul

Page 2 - 1-800-333-1322

8 Generac®Power Systems, Inc.NOTE:Port 1 is for NG only and Port 2 is for LP vaporonly. No provision for simultaneous fuels has beenmade.Serious injur

Page 3 - Power Systems, Inc. 1

Generac®Power Systems, Inc. 9NOTE:For more information about the installation of astandby system, order Engine-Generator StandbyElectric Power Systems

Page 4 - WARNING:

10 Generac®Power Systems, Inc.NOTE:Generac recommends the use of a Generac PowerSystems “GTS” type transfer switch in conjunc-tion with this generator

Page 5 - EXPLOSION HAZARDS

Generac®Power Systems, Inc. 112.10 BATTERY INSTALLATIONStandby generators installed with automatictransfer switches will crank and start automati-call

Page 6 - 4 Generac

12 Generac®Power Systems, Inc.2.11.2 TRANSFER SWITCHIf this generator is used to supply power to any elec-trical system normally powered by an electri

Page 7 - 1.7 ENGINE PROTECTIVE DEVICES

Generac®Power Systems, Inc. 133.2.1 HOURMETERIndicates time the engine-generator has operated, inhours and tenths of hours. Use the hourmeter alongwit

Page 8 - 1.9 LIFTING THE GENERATOR

14 Generac®Power Systems, Inc.If the AUTO/OFF/MANUAL switch is switchedtoo soon, the engine may start. If engine doesstart, it will shut down automati

Page 9 - 1.12 RECONFIGURING THE FUEL

Generac®Power Systems, Inc. 154.2 COOLING SYSTEMAir intake and outlet openings in the generator com-partment must be open and unobstructed for contin-

Page 10 - Power Systems, Inc

16 Generac®Power Systems, Inc.4.5.4 INSPECT COOLING SYSTEM• Inspect engine cooling system at least once eachmonth.• Check hoses for damage, deteriorat

Page 11 - 2.4 BASIC STANDBY ELECTRIC

Generac®Power Systems, Inc. 17Figure 4.3 – Engine Air CleanerSee the “Scheduled Maintenance,” Section 4.7, for aircleaner maintenance.4.5.12 SPARK PLU

Page 12 - 10 Generac

Generac®Power Systems, Inc.INTRODUCTIONThank you for purchasing this model of the standbygenerator set product line by Generac Power Systems. Every ef

Page 13 - 2.10 BATTERY INSTALLATION

18 Generac®Power Systems, Inc.4.6.3 BATTERY MAINTENANCEThe battery should be inspected per the “ScheduledMaintenance,” Section 4.7. The following proc

Page 14 - 3.1 USING A STANDARD “GTS”

Generac®Power Systems, Inc. 19Section 4 — MaintenanceGuardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators4.7 SCHEDULED MAINTENANCEThe following is

Page 15 - 3.5 WEEKLY EXERCISE CYCLE

20 Generac®Power Systems, Inc.Section 4 — MaintenanceGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsMaintenance Level 1 Level 2 Level 3 Level

Page 16 - 4.1 MAINTENANCE PERFORMED BY

Generac®Power Systems, Inc. 21Section 4 — MaintenanceGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsMaintenance Level 1 Level 2 Level 3 Level

Page 17 - OIL DIPSTIC

22 Generac®Power Systems, Inc.Section 5 — TroubleshootingGuardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators5.1 TROUBLESHOOTING POINTSPROBLEM CAU

Page 18 - OIL FILTER

Generac®Power Systems, Inc. 23Section 6 — NotesGuardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators

Page 19 - 4.6 MISCELLANEOUS MAINTENANCE

24 Generac®Power Systems, Inc.Section 6 — NotesGuardian Liquid-cooled 15 kW, 20 kW and 25 kW Generators

Page 20 - 4.6.4 BATTERY REPLACEMENT

Generac®Power Systems, Inc. 25Section 7 - Installation DiagramGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsDrawing No. 0E1533

Page 21 - 4.7 SCHEDULED MAINTENANCE

NBSET EXERCISE SWITCHTERMINAL STRIP 7 POS.VOLTAGE REGULATORVRTS3--SW2-FL-SUPRESSION ASSEMBLYNEUTRAL BLOCKFAULT LIGHTHOUR METERFUSE 15 AMPSFIELD BREAKE

Page 22 - 20 Generac

Generac®Power Systems, Inc. 27Section 8 - Electrical DataGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsWiring Diagram — 1.5L Engine — Drawin

Page 23 - Power Systems, Inc. 21

Table of ContentsGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsGenerac®Power Systems, Inc. 1INTRODUCTION ...I

Page 24 - 5.1 TROUBLESHOOTING POINTS

28 Generac®Power Systems, Inc.Section 8 - Electrical DataGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsWiring Diagram — 1.5L Guardian — Draw

Page 25 - Section 6 — Notes

Generac®Power Systems, Inc. 29Section 8 - Electrical DataGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsElectrical Schematic — 1.5L — Drawing

Page 26

ITEM PART NO. QTY. DESCRIPTION1 098290 1 ASM MOTOR STEPPER2 098941A 1 HOUSING GOVERNOR CONNECTOR3 098958A REF CONNECTOR INTERFACE ASSEMBLY4 098942A 1

Page 27 - Drawing No. 0E1533

ITEM PART NO. QTY. DESCRIPTION1 0D8656 1 BASE,MOUNTING 1.5L STNRD&ACSTC2 027482 2 WASHER SHAKEPROOF EXT 5/16 STL3 070936 2 DAMPENER VIBRATION4 070

Page 28 - Section 8 - Electrical Data

32 Generac®Power Systems, Inc.NUTS ITEM #26.USE LOCTITE ONPANEL FOR ACCESS COVER CABLEWELD STUD UNDER ROOF17GROUND WIRE.FASTENER TO SECUREUSE DOOR LAT

Page 29

ITEM PART NO. QTY. DESCRIPTION1 0D8666 1 ROOF ACSTC&STND CMPRTMNT 1.5L2 0D8664C 1 DUCT, CENTER 1.5L3 0D8657 1 SUPPORT RADIATOR 1.5L MITSU4 0D8660

Page 30

34 Generac®Power Systems, Inc.TYPICAL OF FRONT DUCT & ROOFPANEL. SECURE AS SHOWN. PANEL FOR ACCESS COVER CABLEWELD STUD UNDER ROOF1110"Y"

Page 31

Generac®Power Systems, Inc. 35ITEM PART NO. QTY. DESCRIPTION1 0D8666 1 ROOF, ACSTC&STND CMPRTMNT 1.5L2 0D8664C 1 DUCT, CENTER 1.5L3 0D8657 1 SUPPO

Page 32 - 30 Generac

36 Generac®Power Systems, Inc.Section 9 - Exploded Views and PartsGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsControl Panel — Drawing No.

Page 33 - Power Systems, Inc. 31

Generac®Power Systems, Inc. 37ITEM PART NO. QTY. DESCRIPTION1 0D9322 1 PANEL BACK & BOTTOM GUARDIAN2 0D9332 1 PANEL LH SIDE GUARDIAN & SPRN3 0

Page 34 - 32 Generac

2 Generac®Power Systems, Inc.Study these SAFETY RULES carefully before installing,operating or servicing this equipment. Become familiarwith this Owne

Page 35 - Power Systems, Inc. 33

61WATERPUMPHARDWARE13910112871224101415166325412440394130171110141119171820262120252224573311149247210111014124353436444514711246111049477011106695655

Page 36 - 34 Generac

ITEM PART NO. QTY. DESCRIPTION1 0A4531 1 ENGINE-1.5L2 022473 2 WASHER FLAT 1/4 ZINC4 0A45310258 1 GASKET-EXHAUST MANIFOLD5 0A4355 1 MANIFOLD-EXHAUST6

Page 37 - Power Systems, Inc. 35

14111728(BOTTOM ONLY)"A"28229303229102132273351814123317344TO WATER INLET TUBE(MIDWAY UP ENGINE BLOCK)14TUBE (ON BLOCK)3110232620TO BASE OFW

Page 38 - 36 Generac

ITEM PART NO. QTY. DESCRIPTION1 0D8657 1 SUPPORT, RADIATOR 1.5L MITSU2 0A5734 1 RADIATOR 1.5L3 0A6237 1 VENTURI 1.5L MODINE4* 0A6238 1 GUARD FAN 1.5L

Page 39 - Power Systems, Inc. 37

42 Generac®Power Systems, Inc.2933323118201019L.P. VAPORPORT"OUT 2"4140311149"C"1214161784315"D"452742232764021936303424

Page 40 - Engine — Drawing No. 0E1228-D

Generac®Power Systems, Inc. 43ITEM PART NO. QTY. DESCRIPTION1 * --------- 1 WELDMENT MOUNTING BASE2 075580 1 FLANGE FUEL INLET3 0E1006 1 ASSY REGULATO

Page 41 - Power Systems, Inc. 39

44 Generac®Power Systems, Inc.8361331259151417To BlowerHousing322324351212872233102916301826192031214To EngineCrankshaft26Section 9 - Exploded Views a

Page 42 - 40 Generac

Generac®Power Systems, Inc. 45ITEM PART NO. QTY. DESCRIPTION1 098671 1 ASSY ROTOR 10KW098681 1 ASSY ROTOR 15KW098675 1 ASSY ROTOR 20KW098936 1 ASSY RO

Page 43 - Power Systems, Inc. 41

ITEM PART NO. QTY. DESCRIPTION1 077483 1 BATT 12VDC 75-AH 262 038804D 1 CABLE BATT RED #4 X 20.003 038805B 1 CABLE BATT BLK #4 X 23.004 0742600131 1 A

Page 44 - L.P. VAP

Generac®Power Systems, Inc. 47ITEM PART NO. QTY. DESCRIPTION1 0A4355 1 MANIFOLD EXHAUST 1.5L2 0E2844 1 NIPPLE TOE 1.5NPTX5.5 BLK IRON3 036434 3 BOLT U

Page 45 - Power Systems, Inc. 43

Generac®Power Systems, Inc. 3• Inspect the generator regularly, and promptly repairor replace all worn, damaged or defective parts usingonly factory-a

Page 46 - 44 Generac

48 Generac®Power Systems, Inc.CALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY RIGHTS AND OBLIGATIONSThe California Air Resources Board (CA

Page 47 - Power Systems, Inc. 45

Generac®Power Systems, Inc. 49EMISSION CONTROL SYSTEM WARRANTYEmission Control System Warranty (ECS Warranty) for 1995 and later model year engines:(a

Page 48 - 46 Generac

Part No. 0E1151 Revision F (09/10/03) Printed in U.S.A.Section 10 – WarrantyGuardian Liquid-cooled 15 kW, 20 kW and 25 kW GeneratorsGENERAC POWER SYST

Page 49 - Power Systems, Inc. 47

4 Generac®Power Systems, Inc.1.1 GENERATORThis equipment is a liquid-cooled, engine-driven gen-erator set. The generator is designed to supply elec-tr

Page 50

Generac®Power Systems, Inc. 5Recommended fuels should have a Btu content of atleast 1,000 Btus per cubic foot for natural gas and atleast 2,520 Btus p

Page 51 - Section 10 – Warranty

6 Generac®Power Systems, Inc.Figure 1.6 - Low Coolant Level Sensor1.7.4 OVERSPEED SHUTDOWNThe Pre-pack circuit board on liquid cooled unitsreceives AC

Page 52 - GUARDIAN

1.10 SPECIFICATIONS1.10.1 GENERATOR SPECIFICATIONS1.10.2 ENGINE SPECIFICATIONSMake..................