POWER SYSTEMS, INC.
®
GENERAC
POWER SYSTEMS, INC.
R
R
Installation and
Owner’s Manual
Air-cooled, Prepackaged
Automatic Standby Generators
Models:
004692-0 (8.5 kW)
DEADLY EXHAUST FUMES.
OUTDOOR INSTALLATION ONLY!!
DANGER
Not intended for use as Primary Power in place of utility or in life-
support applications.
!
!
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - Owner’s Manual

POWER SYSTEMS, INC.®GENERACPOWER SYSTEMS, INC.RRInstallation andOwner’s ManualAir-cooled, PrepackagedAutomatic Standby GeneratorsModels:004692-0 (8.5

Page 2 - 1-800-333-1322

1.9 LOCATION1.9.1 GENERATORInstall the generator set, in its protective enclosure,outdoors, where adequate cooling and ventilating airis always availa

Page 3

Generac®Power Systems, Inc. 9amps for 8.5 kW at -17.8º C (0º F) minimum. Whenusing a maintenance-free battery, it is not necessaryto check the specifi

Page 4 - WARNING:

10 Generac®Power Systems, Inc.2. Turn OFF all loads connected to the transferswitch terminals T1 and T2.3. Turn on the utility power supply to the tra

Page 5 - OSION HAZARDS

Generac®Power Systems, Inc. 1115. Set the Auto/Off/Manual switch to OFF. Theengine should shut down.2.5 CHECKING AUTOMATIC OPERATIONTo check the syste

Page 6 - 1.3 SYSTEM SET LED

12 Generac®Power Systems, Inc.Do not make any unnecessary adjustments.Factory settings are correct for most applica-tions. However, when making adjust

Page 7 - 1.4 YOUR GENERATOR

Generac®Power Systems, Inc. 13Section 3 — OperationAir-cooled 8.5 kW Generator3.1 BREAK-IN PROCEDUREOnce the unit has been installed and all electrica

Page 8 - 1.5 SPECIFICATIONS

14 Generac®Power Systems, Inc.Section 3 — OperationAir-cooled 8.5 kW Generator3.4 SEQUENCE OF AUTOMATIC OPERATIONThe generator’s control panel houses

Page 9 - FUEL SYSTEM

Generac®Power Systems, Inc. 153.5.2 TRANSFER BACK TO UTILITY POWERSOURCEWhen utility power has been restored, you will wantto transfer back to that so

Page 10 - 1.11 THE BATTERY

16 Generac®Power Systems, Inc.3.7.3 OVERCRANKThis feature prevents the generator from damagingitself when it continually attempts to start and anoth-e

Page 11 - 2.3 ELECTRICAL CHECKS

Generac®Power Systems, Inc. 174.3 CHANGING THE ENGINE OIL4.3.1 ENGINE OIL RECOMMENDATIONSUse oil of American Petroleum Institute (API) ServiceClass SG

Page 12 - Air-cooled 8.5 kW Generator

Generac®Power Systems, Inc.INTRODUCTIONThank you for purchasing this model of theCenturion product line by Generac Power SystemsInc. This model is a c

Page 13 - (NATURAL GAS ONLY)

18 Generac®Power Systems, Inc.Figure 4.4 — 12 kW and 15 kW EngineAir Cleaner4.6 SPARK PLUG(S)Reset the spark plug(s) gap or replace the sparkplug(s) a

Page 14 - ADJUSTMENT

Generac®Power Systems, Inc. 19Lead-acid batteries present a risk of firebecause they generate hydrogen gas. The following procedures are to be followe

Page 15 - 3.3 AUTOMATIC TRANSFER

20 Generac®Power Systems, Inc.The maximum ambient temperature for your generator is 48.9° C (104° F).4.10 ATTENTION AFTER SUBMERSIONIf the generator h

Page 16 - 3.5 MANUAL TRANSFER OPERATION

Generac®Power Systems, Inc. 21Section 4 — MaintenanceAir-cooled 8.5 kW Generator4.13 SERVICE SCHEDULEATTENTION: It is recommended that all service wo

Page 17 - 3.7 PROTECTION SYSTEMS

22 Generac®Power Systems, Inc.Section 5 — Troubleshooting Air-cooled 8.5 kW Generator5.1 TROUBLESHOOTING GUIDEPROBLEM CAUSE CORRECTIONThe engine will

Page 18 - OIL LEVEL

Generac®Power Systems, Inc. 23Section 6 — Mounting DimensionsAir-cooled 8.5 kW GeneratorDrawing No. 0D3739-ATYPE HOMTYPE HOM120/240v120/240vCBHOM-FCBH

Page 19 - AIR CLEANER

BATTERYCUSTOMER SUPPLIED12VHTOBLACK86LOP85IM21 - 20 Vac Sense TransformerL.E.D - ALARM INDICATORS3 - 50 Hz Operation2 - Remote Not Auto4 - SPARE86REDS

Page 20 - 4.7 BATTERY MAINTENANCE

Generac®Power Systems, Inc. 25CLOSEST TO BEARING04STATORGRD225225141617 15224151710111213 78915A066A345612181419423422435113224AN1225ACONNECTIONMANUAL

Page 21 - 4.9 COOLING SYSTEM

26 Generac®Power Systems, Inc.Section 7 — Electrical DataAir-cooled 8.5 kW GeneratorElectrical Schematic - Drawing No. 0D8501IM1 - IGNITION MODULE, CY

Page 22 - 4.12 CORROSION PROTECTION

21534J221321814161715111312109J17563421152242250224A239IM215A1518SP2240VIM1015194131717152315239SW119415AN1N2221123112211SP144POWER WINDING120V120V33N

Page 23 - 4.13 SERVICE SCHEDULE

Table of ContentsAir-cooled 8.5 kW GeneratorGenerac®Power Systems, Inc. 1Introduction ...Inside Front CoverRead This Manual Thoro

Page 24 - 5.1 TROUBLESHOOTING GUIDE

28 Generac®Power Systems, Inc.AA5123362437493526474649243494332335075143525511551482116762705913494239103592535144754982735225149505149491150161751547

Page 25 - Drawing No. 0D3739-A

Generac®Power Systems, Inc. 29ITEM PART NO. QTY. DESCRIPTION1 0D8312 1 ASSEMBLY, ENCLOSURE BASE 2 0C6735 2 SUPPORT, ROOF FOLDING3 0C7061 1 ENCLOSURE,

Page 26

30 Generac®Power Systems, Inc.3635363763478213893145231124311225221420381530242632101916282717101932283132173231332928132839181040292424141Section 8 —

Page 27

Generac®Power Systems, Inc. 31Section 8 — Exploded Views and Parts ListsAir-cooled 8.5 kW GeneratorEngine & Alternator – Drawing No. 0D8446ITEM PA

Page 28

32 Generac®Power Systems, Inc.17151821221413129783124327292832192365656463626160595852515049484746454443571424138373635343339334023261043425113020662,

Page 29

Generac®Power Systems, Inc. 33ITEM PART NO. QTY. DESCRIPTION1 0C5729 1 ASSEMBLY, CRANKCASE HOUSING WITHSLEEVE2 0C3008 1 SEAL, 38 I.D. CRANKSHAFT 3 090

Page 30

34 Generac®Power Systems, Inc.112112111108107106105104103102100109999295969189908988868583848281130991181141269493117797876777574122125123125119120137

Page 31 - Power Systems, Inc. 29

Generac®Power Systems, Inc. 35ITEM PART NO. QTY. DESCRIPTION74 0C5136A 2 KNOB, AIR CLEANER75 0C3024 1 COVER, AIRBOX NG/LP76 0C3040 1 PRE-CLEANER,77 0C

Page 32

36 Generac®Power Systems, Inc.21462237388,328,92744471013191415352517491415534162336393845482282921171646749232742124544204011143153514302928328294124

Page 33 - Power Systems, Inc. 31

Generac®Power Systems, Inc. 37ITEM PART NO. QTY. DESCRIPTION1 0A9947E 1 CIRCUIT BREAKER 30 X 2 240V SQDQOU230 (7KW)0A9947G 1 CIRCUIT BREAKER 40 X 2 24

Page 34

2 Generac®Power Systems, Inc.Study these SAFETY RULES carefully beforeinstalling, operating or servicing this equipment.Become familiar with this Owne

Page 35 - Power Systems, Inc. 33

ITEM PART NO. QTY. DESCRIPTION1 0D3086 1 BOX GTS LOAD CENTER2 0D3092 1 COVER, 12 POSITION GTS LOAD CENTER3 0C2237 1 TRANSFER SWITCH HOME STANDBY100A2

Page 36

Generac®Power Systems, Inc. 39ITEM PART NO. QTY. DESCRIPTION1 0D5694 1 CASTING, TWIN REGULATOR HOUSING2 0C5765 1 SOLENOID, TWIN REGULATOR3 0C4647 1 GA

Page 37 - Power Systems, Inc. 35

40 Generac®Power Systems, Inc.CALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY RIGHTS AND OBLIGATIONSThe California Air Resources Board (CA

Page 38

Generac®Power Systems, Inc. 41EMISSION CONTROL SYSTEM WARRANTYEmission Control System Warranty (ECS Warranty) for 1995 and later model year engines:(a

Page 39 - Power Systems, Inc. 37

GENERAC POWER SYSTEMS "TWO YEAR" STANDARD WARRANTY FOR ®"PREPACKAGED EMERGENCY AUTOMATIC STANDBY GENERATORS"For a period of two ye

Page 40 - Power Systems, Inc

Generac®Power Systems, Inc. 3ELECTRICAL HAZARDS• All generators covered by this manual producedangerous electrical voltages and can cause fatalelectri

Page 41 - ENGINE ONLY

Section 1 — General InformationAir-cooled 8.5 kW GeneratorOnly qualified electricians or contractors shouldattempt such installations, which must comp

Page 42

Generac®Power Systems, Inc. 5Section 1 — General InformationAir-cooled 8.5 kW Generator1.4 YOUR GENERATORControlPanelAir FilterExhaustEnclosure12 Volt

Page 43 - Section 9 – Warranty

6 Generac®Power Systems, Inc.Section 1 — General InformationAir-cooled 8.5 kW Generator1.5 SPECIFICATIONS1.5.1 GENERATORModel 004692Rated Max. Continu

Page 44

Generac®Power Systems, Inc. 71.6 FUEL REQUIREMENTS AND RECOMMENDATIONSWith LP gas, use only the vapor withdrawal system. This type of system uses the